| Sign In | Join Free | My futurenowinc.com | 
 | 
Brand Name : GINRI
Model Number : JDB-1
Certification : CE CCC
Place of Origin : China
MOQ : 20Pcs
Payment Terms : L/C, T/T, Western Union,Paypal
Supply Ability : 20000Pcs per month
Delivery Time : 1-30 days upon order quantity
Packaging Details : Relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable.
Features : Powered by measuring circuit
Monitoring Function : overcurrent, phase loss, current unbalance
Indicators : 4 LEDS
Rated Voltage : AC24-380V
Mounting : Panel & Screw Fixing
Certifications : CE CCC ISO9000
Fans current limiting relay , 40A Phase Failure Protection Relay Integrative Structure
 
♦ Features
-- Integrative structure
-- Three-phase monitoring of overload, phase loss, phase unbalance
-- Powered by the measuring circuit
-- 1 NC SCR output contact  
-- 4 LEDs for status indication  
 
♦ Protective Functions
-- Overload
-- Phase loss
-- Phase unbalance 
 
♦ Typical Applications
• Pumps • Fans
• Blowers • Motors
• Compressors
 
 
♦ Approvals
• CE • CCC
 
Normal operating conditions and installation conditions
1 , the ambient temperature: -10 °C ~ +50 °C.
2 , relative humidity: ≤ 90%.
3 , atmospheric pressure: 80Kpa ~ 110Kpa.
4 , altitude: not more than 2000 meters.
5 , the grid frequency: 45 ~ 60Hz.
6 , working voltage: 24 ~ 380VAC.
7 , the output interface load capacity: 1A/380VAC.
8 , installation size: in line with JR16 thermal relay standards.
9 , installation location: Any type of installation of type II.
10 . Surrounding environment: Equipment that is resistant to sunlight, rain, snow, wind, sand;
There is a medium with explosion hazard. The air does not contain gases that cause metal corrosion, insulation damage, and conduction.
Medium; No more severe molds and strong vibrations and shocks are allowed.
 
Instructions for use and safety precautions
1 . According to the graphical operation, the AC contactor to the three-phase power line of the motor passes through the three perforations of the protector, and the phase sequence is arbitrary. The terminal of the protector is connected in series to the secondary circuit of the AC contactor. .
2 . First, turn the current regulator knob of the protector clockwise to the position of the maximum scale value. After checking the wiring is correct, start the motor and make it in normal operation. At the same time, the three-phase green luminous tube of the protector is on. The overload red indicator light is not Light, then turn the current adjustment knob slowly counter-clockwise until the overload indicator lights up. At this time, the protector is in the critical state of overload protection. Slowly turn back clockwise until the overload indicator just goes out, then the protector's The scale value of the current adjustment knob is the current value of the motor overload protection.
 
 
♦ Technical data 
 
| Type | JDB-1 | 
| Current range | 2.5-5A,4-10A,8-20A,16-40A,32-80A, | 
| Startup delay | 5s,10s,20s | 
| Protective functions | overload,phase loss,phase unbalance | 
| Setting method | by knob | 
| Indicators | ABC overload&phase loss | 
| Output contacts | 1NC(SCR output) | 
| Contact capacity | 1A 380VAC | 
| Operating voltage of control loop | AC220V or AC380V | 
| Dimensions(H*W*D) | 2.5-40A:38*90*63mm | 
| Mounting | screw fixing | 

|   | 
| Fans current limiting relay , 40A Phase Failure Protection Relay Integrative Structure Images | 
 380 Volt Overcurrent Current Balance Relay Integrative Structure For Blowers
                                                                                    
                        
                        
                        
                                                            380 Volt Overcurrent Current Balance Relay Integrative Structure For Blowers
                                                    
                        
                     Phase Unbalance Current Monitoring Relay Integrative Structure For Compressors
                                                                                    
                        
                        
                        
                                                            Phase Unbalance Current Monitoring Relay Integrative Structure For Compressors
                                                    
                        
                     Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication
                                                                                    
                        
                        
                        
                                                            Overload Current Monitoring Relay 1 NC SCR Output Contact LED Indication
                                                    
                        
                     Unbalance Current Control Relay 220V 380V With Knob Setting Method With 4 LEDS
                                                                                    
                        
                        
                        
                                                            Unbalance Current Control Relay 220V 380V With Knob Setting Method With 4 LEDS
                                                    
                        
                     Electronic Motor Current Monitoring Relay , 3 Phase Overcurrent Relay 220V 50Hz
                                                                                    
                        
                        
                        
                                                            Electronic Motor Current Monitoring Relay , 3 Phase Overcurrent Relay 220V 50Hz
                                                    
                        
                     Phase Failure AC Current Relay CE / CCC Certification With Knob Setting Method
                                                                                    
                        
                        
                        
                                                            Phase Failure AC Current Relay CE / CCC Certification With Knob Setting Method
                                                    
                        
                     380VAC Digital Current Monitoring Relay , Phase Balance Relay 2 C/O Output
                                                                                    
                        
                        
                        
                                                            380VAC Digital Current Monitoring Relay , Phase Balance Relay 2 C/O Output
                                                    
                        
                     Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT
                                                                                    
                        
                        
                        
                                                            Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT
                                                    
                        
                     Under Voltage Current Monitoring Relay Fault Recording Screw Fixing Mounting
                                                                                    
                        
                        
                        
                                                            Under Voltage Current Monitoring Relay Fault Recording Screw Fixing Mounting
                                                    
                        
                     380 Volt Overcurrent Current Balance Relay Integrative Structure For Blowers
                                                                                    
                        
                        
                        
                                                            380 Volt Overcurrent Current Balance Relay Integrative Structure For Blowers